sunjiakang@xxxdjc.com           +86-183 3735 8388         +86 155 1660 9511
Energy Efficiency Standards for Portable Lathes
Home » News » Energy Efficiency Standards for Portable Lathes

Products Catalog

Contact  us

Energy Efficiency Standards for Portable Lathes

Views: 0     Author: Site Editor     Publish Time: 2025-05-29      Origin: Site

The global machine tool industry has implemented tiered energy efficiency requirements for portable lathes since 2022. Key parameters include:

  1. Power Consumption Limits

  • ≤1.5kW for machines with swing diameter <200mm

  • ≤3.0kW for 200-400mm swing models

  • Mandatory auto-idle mode activating after 15 minutes inactivity

  1. Drive System Requirements

  • Servo motors must meet IE4 efficiency class (≥90% full-load efficiency)

  • Inverter duty rating ≥150% for 30 seconds

  1. Testing Protocols

  • ISO 14955-1:2023 measurement methodology

  • Energy consumption measured during:
    • Idle operation (<15% rated power)
    • Cutting 45# steel at 0.2mm/rev feed

Certification Systems

  • EU: CE marking with EN 50598-2 compliance

  • North America: DOE 10 CFR 431 verification

  • Asia: GB 30253-2020 Class 2 minimum


We use cookies to enable all functionalities for best performance during your visit and to improve our services by giving us some insight into how the website is being used. Continued use of our website without having changed your browser settings confirms your acceptance of these cookies. For details please see our privacy policy.
 